Siemens steam turbine exhaust hood spray

WebEach of the two (2) power blocks consists of three (3) gas turbines, three (3) HRSGs, and two (2) steam turbines. The three (3) HRSGs of each block supply high pressure (HP) steam to a header that in turn feeds the two (2) steam turbines. Each HRSG is provided with a start-up bypass valve that directs excess steam to a condenser WebDec 17, 2024 · 1. A. Beevers, F. Congiu, F. Pengue, and T. Mokulys, “ An analysis of the merits of cfd for the performance prediction of a low pressure steam turbine radial …

Steam turbine flow & operation Processing Magazine

WebAug 29, 2024 · The IP turbine exhaust is about 1100°C and 1.2 bar pressure. Both the IHP turbine and the IP turbine produce very high temperature exhaust stream requiring high temperature piping designs. The IP expansion stream is cooled in the HRSG to about 240°C before expansion in the LP turbine. What is exhaust hood temperature in steam turbine? WebJan 26, 2008 · In our plant we have a 100mw siemens make steam turbine.Now there is drop wise condensate leakage in the parting off line near exhaust hood,in running condition it is very diffuclt to locate that point so sir is there any process to locate that point in running condition of turbine. iron horse forwarder https://infotecnicanet.com

Investigation on low-pressure steam turbine exhaust hood …

WebSep 1, 2009 · The document deals with the flow in the exhaust hood of a single flow steam turbine. The effect of the shape of the external case of the hood and the position and … WebElectrical engineer with over five years of professional experience in the field of electrical power, instrumentation, automation, control engineering & project management. Worked with teams of engineers and project managers of companies like General Electric, Allen Bradley, Siemens, Baker Hughes etc. I have demonstrated ability of delivering high value … WebExhaust steam from the HP turbine combined with steam from the IP drum reheated to 1035F. 1.5. ... The Mark VI activates the hood spray system which protects the exhaust section from high temperature. Condensate from downstream of the SJAE condenser and the GSC flows to the LP turbine casing spray. port of pasco commission meeting

Maintainence OF STEAM TURBINE - SlideShare

Category:Exhaust hood for steam turbines-single-flow arrangement

Tags:Siemens steam turbine exhaust hood spray

Siemens steam turbine exhaust hood spray

Cooker hoods and ventilation systems Siemens Home

WebParticipate with commissioning team to commission turbine generator BOP systems including lube oil, seal oil, gland steam, Hydraulic oil, Exhaust hood spray, ... Lead subcontractors to install SIEMENS gas turbines (SGT5-8000H), steam turbine (SST5-5000), generators (SGEN5-2000H) from green field site to erection clearance certificate ... WebGE Steam Turbine Design Philosophy Techology Programs

Siemens steam turbine exhaust hood spray

Did you know?

WebOutput. Up to 250 MW. Main steam conditions. Up to 16.5 MPa / Up to 600°C. Reheat steam conditions. Up to 600°C. Revolutions per minute. 3,000 min -1 (50 Hz) / 3,600 min -1 (60 Hz) Downward exhaust can also be designed if the customer has such requirements. WebNov 1, 2024 · Under the windage condition, the steam in the last stage of steam turbine absorbs energy from rotor blade, which leads to overtemperature of the exhaust steam. …

WebDec 19, 2013 · The generic, IP free, exhaust hood and last stage blade geometries from Burton et al. (2012. “A Generic Low Pressure Exhaust Diffuser for Steam Turbine Research,”Proceedings of the ASME Turbo Expo, Copenhagen, Denmark, Paper No. GT2012-68485) that are representative of modern designs, are used to demonstrate the … WebJan 26, 2014 · The purpose of exhaust hood spray is to decrease the temperature of steam turbine last stage that is probably LP. This is operate on low load specially at start up and shut down of steam turbine when the temperature at the outer most edge of the turbine blades of that stage is very high and As we know that the steam flow also decrease The ...

WebAn exhaust hood is a key component of the local exhaust ventilation system, which is mainly composed of an exhaust hood, duct, fan, and dust removal and purification equipment, as shown in Fig. 2.4. Figure 2.4. Components of an exhaust ventilation system. WebIn order to provide temperature control for the exhaust hood region of low pressure turbines, the exhaust hood sprays are activated in response to measured load and steam exhaust pressure. During start-up of the generator, the sprays always are turned on. During normal operation, the status of the sprays depends on the relative amounts of load ...

WebExhaust spray nozzles help to ensure safe steam turbine operation by protecting the exhaust casing and downstream components from heat damage. Steam turbines can be retrofitted with exhaust spray nozzles, especially when downstream instruments have been damaged by heat, steam flashing is occurring, or downstream components are becoming …

WebSteam Turbine Last Stage and Exhaust Hood, European Conference on Turbomachinery and Fluid Dynamics and Thermodynamics, 2nd, pp.21-27, 1999. [2] J. Linhart and M. Hoznedl, Properties and Improvements of Flow in Steam Turbine Exhaust Hood, Proc.: SUST Shanghai: International Conference on Energy and the Environment, Dec., Shanghai, … iron horse freighthttp://www.turbomachines.net/brochure/siemensindustrialsteam.pdf port of pasir gudangWebThis test was applied to a supercritical, once-reheated, single-shaft, three-cylinder, four-exhaust, condensing 600MW steam turbine. The condenser is a double back pressure, double shell, single flow, surface type condenser. The steam turbine rated main steam temperature is 566°C, and the rated main steam pressure is 24.2MPa. iron horse font free downloadWebNov 1, 2024 · The spray water in exhaust passage of steam turbine during windage is simulated. • The water/steam ratio and operating conditions have a quadratic relationship. • Water spray increases the height and velocity of back flow vortex. • The pressure of the last stage and the pressure ratio of the rotor blade are increased by water spray. • port of pasco small works rosterWebMar 27, 2024 · To investigate the aerodynamic performance of exhaust passage under multi-phase flow, an actual case is conducted in the low-pressure double exhaust passages of 600 MW steam turbine. Then, the flow field is compared and analyzed with and without the built-in extraction pipelines based on the Eulerian–Eulerian homogenous … iron horse golf campWebLOC and Exhaust Hood Spray Systems; Generator System; Generator Seal Oil System (Hydrogen Generator) Generator Cooling System (Hydrogen or TEWAC) ... and site equipment specific preventive maintenance recommendations of the Siemens Energy Large Frame Steam Turbine and its associated systems. More Information. Human … port of pasco washingtonWebExhaust-hood sprays, designed to keep the exhaust diffuser and expansion joint from overheating, inject water into the steam flow immediately downstream of the LSBs. Curtain-water spray systems for quenching high-enthalpy bypass steam introduced to the condenser during startup, shutdown, and/or GT blending in combined cycles with multiple engines. iron horse golf club milton